Kenmore 77022 Owner's Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
DRYER VENTING REQUIREMENTS
WARNING: Toreducetheriskofre,thisdryerMUSTBE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or concealed space
ofabuilding.Onlyrigidorexiblemetalventshallbeused
for exhausting.
Onlya4"(102mm)heavy,metalexhaustventandclamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Mustbefullyextendedandsupportedinnaldryerlocation.
Remove excess to avoid sagging and kinking that may result
inreducedairowandpoorperformance.
Donotinstallinenclosedwalls,ceilings,oroors.
The total length should not exceed 7
3
4
ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal
orexiblemetalvents.Review“VentSystemChart”and,if
necessary, modify existing vent system to achieve best drying
performance.
4"
(102 mm)
4" (102 mm) Heavy, Metal Exhaust Vent
Elbows:
45°elbowsprovidebetterairowthan90°elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Better
Good