Kenmore 70222 Installation Guide Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A). Reinstall
ground conductor screw (A).
B
A
E
1. Prepare to connect neutral ground wire
and neutral wire
B
CE
2. Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and neutral wire (white) (C)
of power supply cord under center terminal block screw (B).
Tighten screw.
A
F
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
3. Connect ground wire
3-wire receptacle (NEMA
type 10-30R)
3-prong plug
Spade terminals with
upturned ends
Ring terminals
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
3-wire Power Supply Cord Connection
Remove center terminal block screw (B).
B
1. Remove center screw
4. Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinstall terminal block cover.
Secure cover with hold down screw. Now, go to “Venting
Requirements.”
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 67 68

Comments to this Manuals

No comments