9
Warranty Safety Operation Cleaning Installation Service Parts
6” ROUND
METAL
DUCT
DUCT TAPE
DECORATIVE
FLUE
FASTEN FLUE TO
UPPER BRACKET
WITH MOUNTING
SCREWS
(3,9x9,5mm)
CONNECT DUCTWORK (ducted conguration only)
1. Adjust the width of the ue mounting bracket
assembly to equal the inside width of decorative
ue. Insert and tighten mounting screws (3,9 X 6
mm) to hold bracket width.
2. Use mounting screws (4,8 x 38 mm) and wall
anchors to secure ue mounting bracket to the
ceiling as shown.
FLUE
MOUNTING
BRACKET
ASSEMBLY
MOUNTING
SCREWS
(3,9x6mm)
MOUNTING
SCREWS
(4,8x38mm)
3. Use 6” round damper / duct connector to 6”
discharge on hood.
4. Attach 6” round metal duct to connect the duct
collar on the hood to the ductwork above.
5. Use duct tape to make all joints secure and air
tight.
6. Insert the decorative ues setting them on the
hood.
7. Extend the upper ue to the ceiling and secure
with two mounting screws (3,9 x 9,5 mm).
WALL
ANCHORS
UPPER
FLUE
LOWER
FLUE
LOUVERS
ON UPPER
FLUE (Slide
down, inside
of lower
ue)