FLUE MOUNTING
BRACKET
MOUNTING
SCREWS
(3,9x6mm)
MOUNTING
SCREWS
(4,8x38mm)
CONNECT DUCTWORK (Non-ducted conguration only)
1. Adjust the width of the ue mounting bracket
assembly to equal the inside width of decorative
ue. Insert and tighten mounting screws (3,9 x 6
mm) to hold bracket width.
2. Use mounting screws (4,8 x 38 mm) and wall
anchors to secure ue mounting bracket assem-
bly to the ceiling as shown.
3. Measure the distance from the top of the hood
outlet to the ceiling - and add 6 inches.
4. Cut a piece of 5” round exible metallic duct
(not included) to the length determined in Step
3. Attach ange to bottom of exible duct and
secure with duct tape.
5. Attach top of exible duct to air bae and
secure with duct tape.
6. Connect the ange to the hood outlet.
7. Turn upper ue section upside down so air vents
are at the top. Slide upper ue section into lower
ue section.
8. Set ue assembly on hood, with top tilted away
from wall. Align (4) holes in bae with (4) holes
in top ue section.
9. Attach bae to upper ue section with (4)
screws (3,4 x 15 mm Flat Head) (included). Use a
short screwdriver.
10. Extend the upper ue section to the ceiling and
secure to upper bracket with (2) mounting screws
(3,9 x 9,5 mm).
UPPER BRACKET
DUCT TAPE
5” ROUND
FLEXIBLE
METAL
DUCT
UPPER
FLUE
SECTION
AIR VENTS
LOWER
FLUE
SECTION
MEASURE
& ADD 6
INCHES
AIR BAFFLE
DUCT
TAPE
FLANGE
HOOD
OUTLET
WALL
AN-
CHORS