Kenmore 75232 Installation Guide Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
D
C
B
A
1. Attach power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL Listed strain relief.
Put the tabs of the two clamp sections (C) into the hole below
the terminal block opening (B) so that one tab is pointing up
(A) and the other is pointing down (D), and hold in place.
Tighten strain relief screws just enough to hold the two clamp
sections (C) together.
Power Supply Cord Strain Relief
POWER SUPPLY CORD CONNECTION
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the strain
relief. The strain relief should have a tight t with the dryer
cabinet and be in a horizontal position. Do not further tighten
strain relief screws at this point.
2. Attach power supply cord to strain relief
4-wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to “4-wire Power Supply Cord
Connection.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to “3-wire Power Supply Cord
Connection.
If your outlet looks like this:
4-wire receptacle (NEMA
type 14-30R)
4-prong plug
Spade terminals with
upturned ends
Ring terminals