Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible portion
of the mobile home structure and must not terminate beneath the mobile
home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct path
outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying
performance:
Use following “Vent System Chart” to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied in “Vent
System Chart.” Exhaust systems longer than those specied will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The “Vent System Chart” provides venting requirements that will help
achieve best drying performance.
Vent System Chart
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Install Vent System
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal exterior
wall opening around exhaust hood.
Connect vent to exhaust hood
2.
Vent must t inside the exhaust hood. Secure vent to exhaust hood
with 4" (102 mm) clamp. Run vent to dryer location using straightest
path possible. Avoid 90° turns. Use clamps to seal all joints. Do not
use duct tape, screws, or other fastening devices that extend into
interior of vent to secure vent, because they can catch lint.
Connect Vent
Connect vent to exhaust outlet
1.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer.
If connecting to existing vent, make sure vent is clean. Dryer vent must
t inside dryer exhaust outlet and exhaust hood. Check that vent is
secured to exhaust hood with a 4" (102 mm) clamp.