_i ec_:s" __,;_t__!eq_,__eme_'_'s_,,
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death_
fire_ or electrical shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet that
cannot be turned off by a switch. Do not use an extension cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn Cooling OFF, and then disconnect the
refrigerator from the electrical source. When you are finished,
reconnect the refrigerator to the electrical source and turn Cooling
ON. See "Using the Controls."
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
TOOLS NEEDED:
Flat-blade screwdriver 1/4"Nut driver
7,_6" and 1/2" Open-end or two 1/4" Drill bit
adjustable wrenches
Cordless drill
IMPORTANT:
All installations must meet local plumbing code requirements.
Do not use a piercing-type or 3_6" (4.76 mm) saddle valve
which reduces water flow and clogs more easily.
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures will remain
above freezing.
For models with water filters, the disposable water filter should
be replaced at least every 6 months.
Water Pressure
A cold water supply with water pressure of between 35 and 120 psi
(241 and 827 kPa) is required to operate the water dispenser and
ice maker. If you have questions about your water pressure, call a
licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 35 and 120 psi (241 and
827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis system
needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than 40 to
60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse osmosis
system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If your refrigerator has a water filter, it may further reduce the
water pressure when used in coniunction with a reverse osmosis
system. Remove the water filter. See "Water Filtration System."
If you have questions about your water pressure, call a licensed,
qualified plumber.
6