Kenmore 625.34867 User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
HOW YOUR WATER SOFTENER WORKS
SECTION 2
11
2A. FACEPLATE TIMER FEATURES
OPTIONAL ADJUSTABLE SETTINGS
Following is a list of other timer features that are
adjustable, and the default setting for each. The
defaults automatically set when electrical power is
applied to the timer. If you want tochange fromany
ofthedefaultvalues,scrollthroughsteps 1 - 5below,
and reset as desired.
1.Pressandholdthe#1SELECTbuttonfor3seconds
until the faceplate display changes. Then, press and
release the #1 SELECT button to display 12 hr.
"12 or 24 Hour clock - defaultsto 12hr: Atthe 12
hr default setting, all time displays are shown in
standard clock time (1 to 12 PM; and 1 to 12 AM). If
military time displays are desired (0100, 0200, etc.),
set to 24 hr by pressing the UP button.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
TIME TIME
AM
PM
2. Press #1 SELECT BUTTON
" Gallon or Liter readings - defaults to gallons:
Waterusageandflowdisplays areshown ingallons.
Ifyouprefertohavethesamedisplaysinliters,press
the UP button until Liter shows.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
GALLONS
LITERS
3. Press #1 SELECT BUTTON
" Maximum Days Between Regenerations -
default is zero days: The faceplate timer automati-
cally controls regeneration frequency (see page
14).Thisprovidesthegreatestoperatingefficiency,
and normally the maximum days feature is not
needed.If youwant tobecertainaregenerationwill
occur within a number of days, use this feature. For
example,if yourwater supply contains ironand you
wantthesoftenertoregenerateatleastonceeveryfew
days to keep the resin bed clean, set the display as
typically shown below. Setting is available from 1 to
15 days by using the UP and DOWN buttons.
NOTE:
Setting a number in this display may override the
function of the water meter andtimer computer (see
page 15). For example,assume the meter/computer
would initiate softener regenerations every 6 or 7
days. If you have maxdays setto 4,as shownbelow,
regenerations will occur every 4 days instead of
every 6 or 7.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
RECHARGE
DAY
default display
example: setto
4 days maxi-
mum between
regenerations
RECHARGE
DAY
4. Press #1 SELECT BUTTON
" CLEANfeatureminutes - defaultis7minutes:
If youhave set this featuretoON (page7),thelength
of the extra backwash cycle automatically sets to 7
minutes.However,youcanadjustthis timefrom1to
15 minutes inlength. If you have a minimum of iron
or sediments, a 3 or 4 minute clean cycle may be
enough to keep the resin bed clean. If you have a
higheramount ofironor sediments,asettingofover
7 minutes maybe needed.To change this cycle time,
usetheUP buttontoincreasethe time,ortheDOWN
button to shorten the time.
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
8
7
6
5
4
3
2
1
SALT
LEVEL
SIGNAL
LEVEL
CLEAN
TIME
MIN
CLEAN
TIME
MIN
default minutes example: time set to 3 minutes
5. Press #1 SELECT to return the present time
display.
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 35 36

Comments to this Manuals