SERVICE TECH. INFORMATION
SECTION 5
24
5A. TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other controller functions. Always make
the initial checks, and the manual initiated diag-
nostics.
NOTES: The faceplate display must show a steady
time(notflashing).IfanErrorcodeshows, firstpress
the#1SELECTbuttontoenterthediagnosticdisplay.
1. Press theON/OFF-HOLDbuttonandhold infor
3 seconds. RECHARGE NOW and FILLbeginto
flash (or clean backwash begins, if set) as the
softener enters the fill cycle of regeneration.
When FILL is on steady, remove the brinewell
cover and, using a flashlight, observe fill water
entering the tank.
a. If water does not enter the tank, look for an ob-
structed nozzle,venturi, fillflow plug, brinetub-
ing, or brine valve riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt storage tank) 0.3 (1.1 liters)
BRINING .16 (.61 liters)
BRINE RINSE
(
f
l
o
w
t
o
d
r
a
i
n
)
.12 (.45 liters)
BACKWASH
(
f
l
o
w
t
o
d
r
a
i
n
)
1.8 (6.8 liters)
FAST RINSE 1.8 (6.8 liters)
2. After observing fill, press the ON/OFF-HOLD
button to move the softener into brining. Aslow
flow of water to thedrain willbegin. Verifybrine
draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable
drop in the liquid level.
NOTE: Be sure a salt bridge is not preventing water
with salt contact.
a. If the softener does not draw brine¼
¼nozzle and/or venturi dirty or defective.
¼nozzle and venturi not seated properly on
gasket.
¼restricted drain (check drain fitting and
hose).
¼defective nozzle and venturi seal.
¼other inner valve defect (rotor seal, rotor &
disc, wave washer, etc.).
NOTE: If water system pressure is low, an elevated
drain hose may cause back pressure, stopping brine
draw.
3. AgainpressON/OFF-HOLDtomovethesoften-
er into backwash. Look for a fast flow of water
from the drain hose.
a. An obstructed flow indicates a plugged top dis-
tributor, backwash flow plug, or drain hose.
4. Press ON/OFF-HOLD to movethe softenerinto
fast rinse. Again look for a fast drainflow. Allow
thesoftenertorinseforafewminutestoflushout
any brine that may remainin theresin tankfrom
the brining cycle test.
5. To return thesoftener toservice, press ON/OFF-
HOLD.
BRINE VALVE
FLOAT SETTING
(Distance from top of resin tank, to top of resin bed.)
FREEBOARD