PLANNtNG
This downdraft blower system is designed to be used to
exhaust airborne contaminants when cooking with a variety
of gas or electric cooktops. It can be mounted in island,
peninsula, or conventional walI locations.
This unit can be easily installed following these basic steps:
® Cut out the countertop opening.
® Mount the unit in the cabinet.
® Connect the ductwork and electrical.
o Install the cooktop.
TYPICAL _NSTA_ON
The high level of air flow of tHs appliance may affect the
gas flame on some types of gas cooktops° This is
NORMAL and win cause no harm, but can be corrected
by lowering the speed of the blower.
TAKE MEASUREMENTS
1= Refer to the cooktop installation instructions for dimensions
of cooktop, countertop cut-out, and cabinet requirements.
The Model 59960 will fit in most 30" wide cabinets and the
Model 59966 will fit in most 36" wide cabinets. However, it
is recommended that oversized cabinets be used for easier
installation.
2= Cooktop depth can vary greatly from one to another. This
may cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference
highlighted above. A countertop with (A) a raised Iip and/or
(B) a backsplash may not allow enough flat countertop for a
proper installation. Note that 2" of fiat countertop is required
behind cooktop and that 1-3/4" is necessary between the back
edge of the cooktop and the inside of cabinet back.
PLAN THE DUCTWORK
1= This downdraft blower system is designed for use with
3-1/4" x 10" ductwork (can be transitioned to 6" round).
Three different discharge directions are available with side-
to-side adiustment for accurate alignment of ductwork.
2. For best performance: Choose the ducting option which
allows the shortest length of ductwork and a minimum
number of elbows and transitions. Check location of floor
ioists, walI studs, electrical wiring or plumbing for possible
interference. NOTE: The unit is shipped with the 3q/4" x
10" discharge facing DOWN. See "CHANGING BLOWER
DISCHARGE" on page 7, if necessary.
3. The system wiII operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart,
above, shows equivalent feet of eibows and transitions.
The number of feet of straight duct pius the equivalent feet
of transitions and/or elbows to be used should equal 40
feet or less.
3.1t_* X 10"
DUCT CONNE_CTOR
A
DOWN@RAFT*"
1¢4f/1,_ fRONTTO_CK __
- tasJ#eCASIN_T#EPT_ /
LE_
D_SCHARGE
f
I
The equivalent feet of various roof and wan caps has been
taken into consideration° Do not include them in this camcu-
mation.
PLAN THE WiRiNG
1= The downdraft blower system draws 4 AMPS and requires
a 120 VAC, 60 Hz circuiL
2= The unit has a 2 fL long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which wiiI
allow the unit's power cord to reach= (Note: If the Model 59940
is being instalIed in a 30" wide cabinet or the Model 59946 is
being installed in a 36" wide cabinet, the outlet cannot be
located on the back waII of cabinet.) Outlet may also be waif
mounted, with access hole in cabinet.