Kenmore 350 series User Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
34
Specifications
FIG. 50
Questions? Call The Kenmore Water Line 1-800-426-9345
Intermittent flow rate does not represent the maximum service flow rate used for determining the soften-
ers rated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate
may affect capacity and efficiency performance.
These systems conform to NSF / ANSI 44 for the specific performance claims as verified and substantiat-
ed by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were efficiency
rated acocording to NSF / ANSI Standard 44.
OTHER SPECIFICATIONS MODEL 38356 MODEL 39356
Type of ion exchange material (resin) high capacity high capacity
Amount of resin (cu. ft.) 0.92 0.92
Rated Softening Capacity (Grains @ Pounds Salt Dose)
14,200 @ 2.8
29,900 @ 8.8
35,600 @ 14.7
14,200 @ 2.8
29,900 @ 8.8
35,600 @ 14.7
Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose) 5060 @ 2.8 5060 @ 2.8
Rated Service Flow Rate (gpm) 8.0 8.0
Pressure Drop at Rated Service Flow Rate (psi) 14 14
Intermittent Flow Rate @ 15 psi (gpm) 8.5 8.5
Max. Drain Flow Rate (gpm) 2.0 2.0
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 47 48

Comments to this Manuals

No comments