SECTION 5
tjjj ,i J J J J J ,i J J J J J ,i J J J J J ,i J
J J J J J J J J J J J J J J J J J J J J J J J
SERVICE TECH. INFORMATION
A. jrouBLESHOOTING
ij.jjjj.jj.jjjj.jj.jjjj
ijjj jj^jj J jjjjj J J
IJJ.^^^SjJ J JJJJJ J J
ijjJVSSjj J jjjjj J J
IJjSduBjJ J JJJJJ J J
ijjjJjjjjjJjjjjjJJ
rjj^jj^jjjj^jj^jjjj^jj^j
UJJJJJJJJJJJJJJJJ
WIRING SCHEMATIC BACK OF TIMER
(PWA)
UT
24VAC
Transformer
'UT POS'TURBINE MOTOR
h Mill
Turbine
Sensor
W.
GNC
+5
“T
valve
motor
Ol
,NC Position
Switch
NO
Keep this manual with your water softener. If repairs are needed, the service technician must have
the information on the following 8 pages. For telephone assistance, call toll free, 1-800-426-9345.
ALWAYS MAKE THESE INITIAL CHECKS FIRST
Does the time display show the correct time of
day?
- - If display is blank, check power source to the
softener.
--If time is flashing, power was off for over 24
hours. The softener resumes normal operation
but regenerations occur at the wrong time.
- - If an error code (Example: Err3) shows in the
faceplate display, go to AUTOMATIC ELEC
TRONIC DIAGNOSTICS, page 5-2.
Plumbing bypass valve(s) must be fully in ser
vice position.
The inlet and outlet pipes must connect to the
softener inlet and outlet respectively.
Is the transformer plugged into a "live",
grounded wall outlet, and the power cable fas
tened securely?
The valve drain hose must be free of kinks and
sharp bends, and not elevated over 8 ft. above the
floor.
^Remove the top cover and salt tank cover.
Is there salt in the storage tank?
Is the brine tubing connected? Brine tubing con
nects to nozzle venturi and brine valve assembly.
I
(See page 6-3, key #83)
3 Is the brine valve float set right? (See page 5-4).
3 Press the SELECT button two times to display
the hardness setting. Be sure it is the correct set
ting for the household's water supply. (Make a
hardness test of the raw water and compare with
the hardness setting. Also test a soft water sam
ple to verify if a problem exists.) Press the SE
LECT button twice more to return to present time
in the display.
If you do not find the problem after making initial
checks, do the MANUAL INITIATED ELEC
TRONIC DIAGNOSTICS, and the MANUAL AD
VANCE REGENERATION CHECK.