MAINTENANCE OF YOUR WATER HEATER
Replacement Parts
IMPORTANT: The following maintenance procedures are for
the FVIR System components and should be performed by a
qualified technician.
Replacement parts may be ordered from Sears Parts and
Service Centers or by calling 1-800-4-MY-HOME (1-800-469
4663). When ordering replacement parts, always have the
following information ready:
1. model, serial, and product number
2. type of gas
3. item number
4. parts description
See the Parts Order List section for a list of available repair parts.
External Inspection & Cleaning of the
Base-Ring Filter
___________________________
1. At least annually, check the base-ring filter (Figure 37) for
any dust or debris that may have accumulated on the filter
screen. NOTE: If the water heater is located in an area that
is subjected to lint and dirt, it may be necessary to check
the base-ring filter more frequently.
2. Follow the Lighting Instructions to turn off the water heater
and allow it to cool for 10 minutes before attempting to clean
the base-ring filter.
3. Use a vacuum cleaner with a hose attachment to remove
any dust or debris that may have accumulated on the filter.
NOTE: If unable to inspect or clean the base-ring filter, follow
the “Cleaning the Combustion Chamber and Flame-arrestor”
instructions.
4. After the base-ring filter has been cleaned, follow the
Lighting Instructions to return the water heater to service.
Removing the Manifold/Burner Assembly
1. Turn off the gas supply to the water heater at the manual
gas shut-off valve. This valve is typically located beside the
water heater (Figure 11). Note the position of the shut-off
valve in the open/on position then proceed to turn it off.
2. Turn the temperature dial to the “OFF” position.
GAS CONTROL VALVE/
THERMOSTAT
5. Disconnect the following from the gas control valve/thermostat:
thermopile plug, tank sensor plug, igniter wire plug, pilot tube,
and manifold tube. (See Figures 32 & 33.)
6. Grasp the manifold tube and push down slightly to free the
manifold and pilot tubes.
7. Carefully remove the manifold/burner assembly from the
burner compartment. NOTE: Be sure not to damage internal
parts.
Removing the Burner from the Manifold/
Burner Assembly
__________________________
1. Take off the burner by removing the two (2) screws located
underneath the burner.
2. Check the burner to see if it is dirty or clogged. The burner
may be cleaned with soap and hot water (Figure 34).
BURNER
(BOTTOM VIEW)
FIGURE 34.
ELECTRONIC CONTROL MODULE
O
TANK SENSOR
PLUG
1 , -
THERMOPILE \
PLUG MANIFOLD
TUBE TUBE
FIGURE 32.
3. Remove the outer door.
4. Remove the two screws securing the manifold door
assembly to the combustion chamber (Figure 33).
Replacing the Pilot/ Pilot Tube Assembly
1. Remove the manifold assembly. See “Removing the
Manifold/Burner Assembly.”
2. Remove the retainer clip from the back of the two piece
wire connector (using a flat blade screw driver), then
remove the two piece wire connector from the manifold
door (Figure 35).
IMPORTANT: Be careful not to bend or alter the position of
the pilot tube. It will be used as a bending template for the
new pilot assembly.
3. Remove the burner by removing the two (2) screws located
beneath it. Keep the screws for future use.