Kenmore Coldspot 106 User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NLC250/NLC250
Tested and certified by NSF Internationa! against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity; 250 Gallons (946 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction
U.S. ERA
Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects
MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 1.9 mg/L N/A 0.04 mg/L N/A 97.9% 994707
Particulate
N/A 610,000/mL* N/A 154/mL N/A 99.97% 994711
Contaminant
U.S. ERA
Average Maximum Average Minimum % Average % NSF Test
Reduction
MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%“ 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity
0.5 NTU
29 NTU
0.1 NTU 0.09 NTU 99.5% 99.69% 994710
Lead: @ pH 6.5
0.015 mg/L
0.16 mg/L“* 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @ pH 8.5
0.015 mg/L 0.16 mg/L*“ 0.002 mg/L 0.001 mg/L 98.8% 99.4% 994709
Base Grille Water Filtration System Model WF-LC400/LC400
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 400 Gallons (1514 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) < ( 60 psi.
Substance Reduction
U.S. ERA
Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects
MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 2.0 mg/L N/A 0.04 mg/L N/A 98% 994707
Particulate
N/A 610,000/mL* N/A 154/mL N/A 99% 994711
Contaminant
U.S. ERA
Average Maximum Average Minimum % Average % NSF Test
Reduction
MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%“ 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity
0.5 NTU
29 NTU
0.12 NTU 0.09 NTU 99.59% 99.69% 994710
Lead: @ pH 6.5
0.015 mg/L
0.16 mg/L*“ 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @ pH 8.5 0.015 mg/L 0.16 mg/L*“ 0.002 mg/L 0.001 mg/L 98.8% 99.4% 994709
■ Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30- 120 psi (207 - 827 kPa)
Water Temperature OS'* -100°F (O.e” - ST.S” C)
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NLC250 Change cartridge at least every 6-9
months. Use replacement cartridge NLC 250, part# 9902.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Model WF-LC400 The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400, part#
9902. 2000 suggested retail price of $39.95 U.S.A./$49.95
Canada.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the “Assistance or Service” section for the
Manufacturer’s name, address and telephone number.
‘Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. “Cyst performance is % reduction based on NSF Standard 53. ‘“Test
requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
24
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 75 76

Comments to this Manuals

No comments