Kenmore 505 User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
HIGH ALTITUDE INSTALLATIONS
Set dip switches 2 and 3 to the values shown in table
below for your altitude. The default setting for the
appliance is 0-2000 ft (0-610 m) with switches No. 2 and
No. 3 in the OFF position.
A WARNING
DO NOT adjust the other dip switches uniess specificaliy
instructed to do so.
The 2-Unit connection cable is an optional accessory
that connects 2 water heaters and allows them to
function as one hot water source.
The Multi-Unit connection kit and Multi-Unit connection
cables are optional accessories that connect 2 to 5
water heaters and allow them to function as one hot
water source.
The Multi-Unit connection kit includes a PC board and
one Multi-Unit connection cable.
Refer to the instructions that come with the accessory
for complete installation information.
Guidelines
Do not install both the 2-Unit connection cable and the
Multi-Unit connection kit because they are not designed
to operate together.
Water heaters should be installed less than 18 inches
apart so that the cables will reach between units and to
prevent temperature fluctuations (cold water sandwich
effect) when the water is shut off and turned back on.
Temperature settings can only be changed on the
controller for the primary unit.
Table 8:
Number of Connected Water Heaters: Accessories Necessary:
2 (1) 2-Unit connection cable or (1) Multi-Unit connection kit
3 (1) Multi-Unit connection kit and (1) Multi-Unit connection cable
4 (1) Multi-Unit connection kit and (2) Multi-Unit connection cables
5 (1) Multi-Unit connection kit and (3) Multi-Unit connection cables
22 305 & 505 Indoor Manual
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 35 36

Comments to this Manuals

No comments