Performance Data Sheet
Kenmore
®
46-9970
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the
reduction of substances listed below.
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (21.9 lpm)
Water Supply Potable Water
Water Pressure 40-120 psi (2.8-8.2 bar)
Water Temperature 33°F-100°F (0.6°C-38°C)
Note: While the testing was performed under standard laboratory conditions, actual
performance may vary.
WARNING
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before and after the system. Systems certied for cyst reduction
may be used on disinfected water that may contain lterable cysts. EPA Establishment Number
10350-MN-005.
NOTICE
To reduce the risk associated with property damage due to water leakage:
Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure exceeds 80 psi,
you must install a pressure-limiting valve. Contact a plumbing professional if you are uncertain
how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you are uncertain how
to check for this condition.
Do not install on hot water supply lines. The maximum operating water temperature of this lter
system is 100º F (38º C).
Protect lter from freezing. Drain lter when temperatures drop
below 3F (0.6ºC).
The disposable lter cartridge must be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction in ow rate occurs.
For conditions of use, health claims certified by the California Department of Public Health, and
replacements, see performance data sheet. California Department of Public Health Certification
#05-1698. The contaminants or other substances removed or reduced by this water filter are not
necessarily in all users’ water.
Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined by NSF testing.
Substance Tested
for Reduction Average Inuent
NSF specied
Challenge Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduc-
tion
Requirements
NSF
Test Report
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.5% 0.05 mg/L N/A ≥ 50% J-00077703
Nominal Particulate Class I, ,
≥0.5 to < 1.0 µm 7,833,333 pts/mL At least 10,000 particles/mL 99.7% 18,617 pts/mL N/A ≥85% J-00077704
Cyst* 101,000 cysts/L Minimum 50,000 cysts/L 99.99% 1 cyst/L N/A ≥99.95% J-00100036
Asbestos 47 MF/L
107 to 108 bers/L; bers
greater than 10 µm in length >99% <1 MF/L N/A ≥99% J-00077707
Atrazine 0.009 mg/L 0.009 mg/L ± 10% 94.5% 0.0005 mg/L 0.003 mg/L N/A J-00077708
Benzene 0.016 mg/L 0.015 mg/L ± 10%± 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00077717
Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 98.7% 0.001 mg/L 0.04 mg/L N/A J-00077718
Endrin 0.007 mg/L 0.006 mg/L ± 10% 97.1% 0.0002 mg/L 0.002 mg/L N/A J-00100039
Lead @ pH 6.5 0.152 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077722
Lead @ pH 8.5 0.148 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077723
Lindane 0.002 mg/L 0.002 mg/L ± 10% 99.0% 0.00002 mg/L 0.0002 mg/L N/A J-00077726
Mercury @ pH 6.5 0.0058 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00100037
Mercury @ pH 8.5 0.0061 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00092355
P-Dichlorobenzene 0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.005 mg/L 0.075 mg/L N/A J-00077729
Tetrachloroethylene 0.015 mg/L 0.015 mg/L ± 10% 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00082184
Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.2% 0.001 mg/L 0.003 mg/L N/A J-00077730
2,4-D 0.218 mg/L 0.210 mg/L ± 10% 99.5% 0.0009 mg/L 0.07 mg/L N/A J-00085470
*Based on the use of Cryptosporidium parvum oocysts.
Tested and certied by NSF International
against NSF/ANSI Standard 42 and
Standard 53 in model GE PLWF for the
reduction of the claims specied on the
performance data sheet.
REPLACEMENT