30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
3
Electrical Connection to the Range
This appliance is manufactured with the neutral
terminal connected to the frame.
Three Conductor Wire Connection to Range
If local codes permit connection of the frame
grounding conductor to the neutral wire of the
copper power supply cord (see Fig. 3):
1. Remove the 3 screws at the lower end of the
rear wire cover, then bend the lower end of the
rear wire cover (access cover) upward to expose
range terminal connection block (see Fig. 2).
2. Using the nuts supplied in the literature package,
connect the neutral of copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to
the outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal) (see
Fig. 3).
3. Lower the terminal cover and replace the 3
screws.
Cord
Mounting
Plate
Cord
Mounting
Plate
A
supplied by the
must be installed at
this location
strainrelief
user
Terminal
Block
To 240 V
receptacle
White Wire
(Neutral)
Grounding
Strap
Black
wire
Red wire
Silver colored Terminal
1-1/8“ Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8“ Dia.
Cord Kit Hole
Figure 3
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of
the frame grounding conductor to the neutral wire
of the copper power supply cord (see Fig. 4)
1. Remove the 3 screws at the lower end of the
rear wire cover, then raise the lower end of the
rear wire cover (access cover) upward to expose
range terminal connection block (see Fig. 2).
2. Remove the ground strap from the terminal block
and from the appliance frame.
3. Using the nuts supplied in the literature package,
connect the ground wire (green) of copper power
supply cord to the frame of the appliance with
the ground screw, using the hole in the frame
where the ground strap was removed (see Fig. 4).
4. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to
the outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
5. Lower the terminal cover and replace the 3
screws.
Figure 4
1-1/8“ Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8“ Dia.
Cord Kit Hole
NOTE: Be sure to remove the supplied
grounding strap
To 240 V receptacle
Terminal Block
Silver Colored
Terminal
Red
Wire
White Wire
(Neutral)
Ground
(Bare
or Green
Wire)
Copper
Black wire
A
supplied by the
must be installed at
this location
strainrelief
user