ERROR CODES WIRELESS REMOTE MONITORING STATION
Error
Code
EO
E1
w
eF
Error Type
Temperature
Sensor
Defrost
Sensor
Humidity
Sensor
Pump Drain
Possible Causes
1. Sudden change
in the
surrounding
temperature.
2. Faulty sensor.
. Improper
bucket
installation.
. Blockage to
drain hose
system.
. Back flow of
water through
pump drain
hose.
. Improper pump
drain hose
installation.
. Faulty drain
pump.
Corrective Actions
1. Unplug the dehumidifier.
2. Check the surrounding area for possible
reasons for sudden temperature changes.
3. Wait 30 minutes before plugging the
dehumidifier back in and resuming normal
operation.
4. If the “Error” is still indicated, please
contact your nearest service center.
1. Unplug the dehumidifier.
2. Remove the bucket.
3. Check to make sure that there is nothing
blocking the connection at the base of the
pump or the bucket.
4. Reinstall the bucket, taking care that it is
installed properly.
5. Check to make sure that the pump drain
hose is not crimped or blocked.
6. Check to make sure that the pump drain
hose is not both under water and sitting at
a height above the dehumidifier - this can
cause a “back flow” of water from the hose
to the dehumidifier.
7. Remove and reinstall the pump drain hose,
taking care that the pump drain hose is
installed properly.
8. Plug the dehumidifier in and restart
9. If the “E3” error is still indicated, please
contact your nearest service center.
The remote monitoring station is a receiver
with a receiving range of only 330 feet in
open air with no obstructions. Actual receiving
range will vary depending on what is in
the path of the signal transmitted from the
dehumidifier unit. Each obstruction (roof,
walls, floors, ceilings, thick trees, etc.) will
effectively cut signal range in half.
Example: The wireless remote monitor with
a 330-foot range is mounted on an interior
wall or placed on a countertop so the signal
from the dehumidifier has to pass through one
basement wall, across the 10-foot width of the
room through the room’s other wall and then
through the floor to the room upstairs where
the receiver is located. The first wall
will reduce the range to 165 feet, and the
second wall will reduce the range to 87 feet.
Factoring in the 10-foot room, this leaves
a maximum of 77 feet of remaining signal
range. Passing up through the floor has now
reduced the effective range to 38 feet.
Typically this allowance is enough for most
frame-constructed homes; however certain
materials can reduce range even further.
Metal siding, stucco, and some types of
glass can reduce signal range by as much
as 75% compared to the 50% reduction
typical of most obstructions. It is possible
to receive a signal through these materials;
however maximum range will be much less,
due to their tendency to absorb or reflect
a much larger portion of the dehumidifier’s
signal.
NOTE: You may have to move the monitor
closer to the main unit if it is not receiving a
proper signal following set-up procedures.
PRODUCT SPECIFICATIONS
Classification
Spec
Remark
Model 251.90701
Power Supply AC 115V/60(Hz)
Moisture Removal 70 Pint(33.1 liters) 24-Hour Period
Control Type Electronic
Refrigerant R410A/11.29 oz. 320g
Humidity
Display
Humidity Setting: 35%-70%
Display Range: 20%-90%
5% Increments
1% Increments. Current Humidity.
Temperature
Display
Display Range: Lo, 36-99°F, Hi 1° F Increments. Current Temp.
Display Range: Lo, 2-37°C, Hi 1° C Increments. Current Temp.
Timed Shut-off Setting Range: 1Hr-12Hr 1 Hour Increments
Fan Motor Speed 3 Speeds Auto/High/Low
Dimensions 15.74x25.59x13.6 in 400x650x346mm
Net Weight 49 lbs 22.3Kg
Operating Temp. 36^-99^
Drain Pump 12V DC
Pump Drain Hose .25 in X 18 ft 6.35x5,486mm
Setup Guide
Insert the batteries in the monitor. After
the batteries are inserted, the Monitoring
Station will start receiving signal data from
the dehumidifier: temperature, humidity, etc.
should be displayed on the monitor’s screen.
If this doesn't happen after 2 minutes, check
the dehumidifier to make sure it is operating
properly. Remove the batteries from the
monitor, wait a minute, then replace.
Batteries
iiBi <
OS: 00
O
111
Oj^
TEMPEi?ATUi?E
ijrf
Ou
(jn
IO
-
(3 Receiver On
Battery Strength
Sound Aiert
Time of Day
Fan On
O Bucket Fuii
O Pump On
O Temperature
O Humidity
O Waii Hanger