INSTALLATION INSTRUCTIONS
KEY DIMENSIONS AND SPECIFICATIONS
LOCATION REQUIREMENTS
IMPORTANT: Read all installation instructions
completely before installing and operating your dryer.
It is important that you review this entire manual before
installing and using your dryer. It contains detailed
instructions concerning electrical connections, gas
connections and exhaust requirements.
CHOOSE THE PROPER LOCATION
Store and install the dryer where it will not be exposed
to temperatures below freezing or exposed to outdoor
weather conditions.
Choose a location with a solid, level oor.
If the dryer is being installed in a garage, place the
dryer at least 18 inches (45.7cm) above the oor.
Properly ground the dryer to conform with all
governing codes and ordinances.
To reduce the risk of electric shock, do not install the
dryer in damp or wet locations.
NOTE: Installing the dryer in a humid space, or installing or
storing the dryer where it will be exposed to the weather or
freezing temperatures, may result in rust or other dam-
age that is not covered by the product warranty.
IMPORTANT: If you are installing your dryer in a
manufactured or mobile home, please refer to the
Special Electrical Requirements for Mobile or
Manufactured Homes section.
CLEARANCES
Most installations require a minimum 5 inch (12.7 cm)
clearance behind the dryer for the exhaust ducting.
Allow minimum clearances of at least 1 inch (2.5 cm)
on the sides and back to minimize vibration and noise.
Allowing additional clearance for installation and
servicing is recommended.
Be sure to allow for wall, door, or oor moldings that
may increase the required clearances.
Allow at least 22 ½ inches (57.3 cm) in front of the
dryer to open the door.
Additional instructions for closet installations:
The closet door must allow for su cient air ow. Refer to the
diagram above for minimum vent opening requirements. A
louvered door is also acceptable.
Description Dryer (Gas and Electric)
Electrical Requirements Refer to the rating label
Gas Requirements* NG: 4–10.5 inches WC (Water Column)
Gas Requirements* LP: 8–13 inches WC
Dimensions 27 in. (W) X 30
1/4
in. (D) X 38
11
/
16
in. (H), 51
3
/
16
in. (D with door open)
68.6 cm (W) X 76.7 cm (D) X 98.3 cm (H), 130 cm (D with door open)
Net Weight Electric : 133.6 lb. (60.6 kg) Gas : 137.6 lb. (62.4 kg)
Drying Capacity IEC 7.4 cu. ft.
*Gas Models Only
22 1/2 in.
(57.3 cm)
30 1/4 in.
(76.7 cm)
5 in.
(12.7 cm)
5 in.
(12.7 cm)
51 3/16 in.
(130 cm)
1 in.
(2.5 cm)
1 in.
(2.5 cm)
27 in.
(68.6 cm)
48 sq. in.
(310 sq. cm.)
24 sq. in.
(155 sq. cm.
)
3"
(7.6 cm)
3"
(7.6 cm)
Vent
Vent
Standard Installation – Side View
Standard Installation – Front View