Facts to Consider About
the Location
Carefully choose an Indoor location for the new water heater,
because the placement is a very important consideration for
the safety of the occupants in the building and for the most
economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed;
Select a location indoors as close as practical to the gas
vent or chimney to which the water heater vent is going to be
connected, and as centralized with the water piping system
as possible.
Selected location must provide adequate clearances for
servicing and proper operation of the water heater.
CAUTION
Property Damage Hazard
AH water heaters eventually leak
Do notinstali without adequate drainage
Installation of the water heater must be accomplished in such a
manner that if the tank or any connections should leak, the flow
will not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan
should be installed under the water heater. Drain pans are
available at your local Sears or hardware store. Such a drain
pan must have a minimum length and width of at least 2 inches
(51 mm) greater that the water heater dimensions and must be
piped to an adequate drain. The pan must not restrict
combustion air flow.
A WARNING
Fire or Explosion Hazard
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Avoid ail ignition sources if you smell LP gas.
Do not expose water heater control to excessive gas
pressure,
Useonlygasshownon rating plate.
Maintain required clearances to combustibles.
Keep ignition sources away from faucets after
extended period of non-use.
è
Read instruction manual before
Installing, using or servicing
water heater.
W I
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.);
Flammable liquids (such as gasoline, solvents, propane [LP or
butane, etc.] and other substances such as adhesives, etc.)
emit flammable vapors which can be ignited by a gas water
heater’s pilot light or main burner. The resulting flashback and
fire can cause death or serious burns to anyone in the area.
Even though this water heater is a flammable vapors ignition
resistant water heater and is designed to reduce the chances
of flammable vapors being ignited, gasoline and other
flammable substances should never be stored or used in the
same vicinity or area containing a gas water heater or other
open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
AWARNING
Fire Hazard
For continued protection against
risk of fire:
•Do not install water heater on
carpeted floor,
•Do not operate water heater if
flood damaged.
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath
the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2 mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire floor
must be covered by the panel. Failure to heed this warning may
result in a fire hazard.
Awarning
à
Fire or Explosion Hazard
Read instruction manual before installing
using or servicing water heater.
Improper use may result in fire or
explosion
Maintain required clearances to
combustibles.
Minimum clearances between the water heater and combustible
construction are 0 inch at the sides and rear, 4 inches
(102 mm) at the front, and 6 inches (153 mm) from the vent
pipe, see Figure 8. Clearance from the top of the jacket is 12
inches (305 mm) on most models. Note that a lesser dimension
may be allowed on some models, refer to the label attached
adjacent to the gas control valve on the water heater.
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 31 32

Comments to this Manuals

No comments

Rockwell Automation 140G_MG- General Warning for Trip Units manuales

Manuales del propietario y guías del usuario para Equipo Rockwell Automation 140G_MG- General Warning for Trip Units.
Ofrecemos 1 manuales en pdf Rockwell Automation 140G_MG- General Warning for Trip Units para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Equipo Rockwell Automation

Modelos Tipo de documento
22-HIM-C2S PowerFlex 4-Class Remote Small HIM Manual de usuario     Rockwell Automation 22-HIM-C2S PowerFlex 4-Class Remote Small HIM User Manual, 4 paginas
100-C43...55 Contactors 12-24V Box Manual de usuario   Rockwell Automation 100-C43...55 Contactors 12-24V Box User Manual, 1 paginas
20P PowerFlex DC Drive - Frame D Field Dual Diode Manual de usuario   Rockwell Automation 20P PowerFlex DC Drive - Frame D Field Dual Diode Module User Manual, 8 paginas
22C PowerFlex 400 Replacement Fan Manual de usuario     Rockwell Automation 22C PowerFlex 400 Replacement Fan User Manual, 4 paginas
140G-N-PL Padlock Attachment Manual de usuario   Rockwell Automation 140G-N-PL Padlock Attachment User Manual, 3 paginas
22B PowerFlex 40 Custom Firmware Inst. - Option AF Manual de usuario   Rockwell Automation 22B PowerFlex 40 Custom Firmware Inst. - Option AF User Manual, 4 paginas
20D PowerFlex 700S Auxiliary Control Power Supply Manual de usuario   Rockwell Automation 20D PowerFlex 700S Auxiliary Control Power Supply User Manual, 4 paginas
44N Zone Control Photoelectric Sensors Manual de usuario   Rockwell Automation 44N Zone Control Photoelectric Sensors User Manual, 4 paginas
100-DMD02 Bul 100 Mechanical Interlock Kit Manual de usuario   Rockwell Automation 100-DMD02 Bul 100 Mechanical Interlock Kit User Manual, 2 paginas
48MS MultiSight Vision Sensor Manual de usuario   Rockwell Automation 48MS MultiSight Vision Sensor User Manual, 76 paginas
20P PowerFlex DC Drive - Frame B Field Dual Diode Manual de usuario   Rockwell Automation 20P PowerFlex DC Drive - Frame B Field Dual Diode Module User Manual, 14 paginas
42CRC Color Registration Control Manual de usuario   Rockwell Automation 42CRC Color Registration Control User Manual, 24 paginas
20P PowerFlex DC Drive - Frame A Field Circuit Boa Manual de usuario   Rockwell Automation 20P PowerFlex DC Drive - Frame A Field Circuit Board User Manual, 20 paginas
20P PowerFlex DC Drive - Frame D Field SCR Module Manual de usuario   Rockwell Automation 20P PowerFlex DC Drive - Frame D Field SCR Module User Manual, 8 paginas
20L-RESPRE-A1 PowerFlex 700L Frame 3A and 3B Input Manual de usuario   Rockwell Automation 20L-RESPRE-A1 PowerFlex 700L Frame 3A and 3B Input Filter Precharge Resistor Kit User Manual, 8 paginas
20D-DL2-CL3 DriveLogix Controller Compact I/O Cabl Manual de usuario   Rockwell Automation 20D-DL2-CL3 DriveLogix Controller Compact I/O Cable User Manual, 12 paginas
22D PowerFlex 40P Quick Start - FRN 1.xx - 3.xx Manual de usuario       Rockwell Automation 22D PowerFlex 40P Quick Start - FRN 1.xx - 3.xx User Manual, 129 paginas
22A PowerFlex 4 Custom Firmware - DA Option Manual de usuario   Rockwell Automation 22A PowerFlex 4 Custom Firmware - DA Option User Manual, 5 paginas
22B PowerFlex 40 Comm Cover Manual de usuario   Rockwell Automation 22B PowerFlex 40 Comm Cover User Manual, 2 paginas
PF700 PowerFlex 700 Drive Components Replacement - Manual de usuario   Rockwell Automation PF700 PowerFlex 700 Drive Components Replacement - Frame 9 User Manual, 84 paginas