Page view 11
I
OPERAT
J
WATER LEVEL CHECK
1,
2.
Turn on the water supply at the saddle valve.
Water should now flow into reservoir. If not,
check that saddle valve is open. Check for leaks
at all connections.
Allow Reservoir to fill and check that water level
is correct. The water level should be between the
two marks on the front side of the reservoir divider
(Fig 25). If the water level is not between the two
marks a float adjustment may be required. Refer
to the Adjusting Float instructions found in the
Maintenance Section on Page 13 to adjust float.
4.
Test - Turn on the electricity at the fuse box, turn
the humidifier power switch to the “ON” position
and turn humidistat knob to the “TEST” position.
The humidifier blower should operate and the
media wheel should rotate slowly at approximately
one (1) revolution per minute. The furnace may
have to be running for the humidifier to operate,
depending on the wiring method used.
install front panel by sliding top of panel into
channel in upper case. Swing panel bottom in
and down to engage channel in lower case.
HUMIDISTAT
1, Set the knob to the lowest outdoor temperature
expected for a 24-hour period. Because of differ
ences in house construction, you may want to try
a higher or lower setting to achieve proper
humidity (Fig 26).
K-w
SPP
emram,
u'<(i
mmsm
FOB, MI'Xf
LLAVi U,M '..I nr. •
»BIT»«
Fig. 26
Change the knob settings as outdoor
temperature changes occur.
WARNING: Do not leave the knob in the in the
“TEST” position above “+20” or the humidifier will run
constantly.
If sweating of windows or walls occurs:
1. Check the indicator setting. The indicator should
point to the number that represents the lowest
expected 24-hour outdoor temperature. Wait 24
hours before changing the indicator setting.
2. If the indicator setting in Step 1 is correct, and
conditions have not changed, rotate the knob
back and forth from the “TEST” to minimum
humidity setting. If the humidifier goes on and
off, the control is operating properly.
3. Remember, to increase the indoor relative
humidity, turn the indicator clockwise ^ .
To decrease indoor relative humidity, turn
counter-clockwise ^ .
NOTE: Because of differences in home construction,
the number of occupants, and living habits in some
homes, when the anticipated 24-hour lowest outdoor
temperature is,for example, +10°F, your ideal humidi
stat setting may be the low position.
12